Split-core Open-loop Hall Sensor
Get Latest PricePayment Type: | T/T,Money Gram |
Transportation: | Ocean,Air,Express,Land |
Payment Type: | T/T,Money Gram |
Transportation: | Ocean,Air,Express,Land |
Model No.: THK_EKA15D4
Place Of Origin: China
Use: Electronic
Coil Structure: Toroidal
Product introduction: | Application: |
Ø Removable structure Ø Power supply: ± 12 ~ 15V DC Ø Hall effect principle - Open Loop Current Sensor; Ø The primary and secondary of the current sensor are insulated and can measure DC, AC, pulse, etc; | Ø Application on Inverter Ø AC/DC variable speed drive Ø Switching power supply (SMPS) Ø UPS uninterruptible power supply Ø Current monitoring and control of induction cooker |
Electrical characteristics:
Parameter | Symbol | THK50 EKA15D4 | THK100 EKA15D4 | THK200 EKA15D4 | THK300 EKA15D4 | THK400 EKA15D4 | THK600 EKA15D4 |
Rated current | IPN(A) | 50 | 100 | 200 | 300 | 400 | 600 |
Measuring range | IP(A) | 0~±150 | 0~±300 | 0~±600 | 0~±900 | 0~±900 | 0~±900 |
Output voltage | VO(V) | ±4.0*(IP/IPN) | |||||
Load resistance | RL(kΩ) | >10 | |||||
Working power supply | VC(V) | ±12V~±15V DC±5% | |||||
Insulation voltage | VD(V) | 50/60Hz,1min,2.5kV;RMS |
General parameters:
Project | Condition | Date | Unit | |
Accuracy XG | @ IPN,T=25℃ | <±1.0 | % | |
Accuracy XG | @ IPN,T=40~+85℃ relative to 25℃ | <±2.0 | % | |
Offset voltage VOE | @ IP=0,T=25℃ | <±25 | mV | |
Voltage offset temperature drift VOT | @ IP=0,-40~+85℃ | <±1.0 | mV/℃ | |
Hysteresis offset voltage VOH | @ IP=0,after 1*IPN | <±15 | mV | |
Linearity εr |
| ≤1.0 | %FS | |
Follow accuracy di/dt |
| >100 | A/µs | |
Response time tra | @ 90% of IPN | <5.0 | µs | |
Operating bandwidth BW | -3dB | DC-20 | kHZ | |
Working temperature TA |
| -40~+85 | ℃ | |
Storage temperature TS |
| -55~+125 | ℃ | |
Static power consumption IC |
| 15+Is | mA | |
Product weight m |
| 70 | g | |
Shell material | PBT material containing 30% glass fiber, flame retardant grade: UL94- V0; |
| ||
Standard | IEC60950-1:2001 EN50178:1998 SJ20790-2000 |
| ||
Structural drawing: (mm)
Connection diagram:
Remarks:
1. When the measured current passes through the primary pin of the sensor, there is a corresponding voltage signal output at the output end;(Note: wrong wiring may damage the sensor)
2. Products with different rated current can be designed according to the requirements of customers, and the output voltage of the sensor can be selected;
3. When the busbar is fully filled with holes, the dynamic performance is the best;
4. The temperature of primary conductor shall not exceed 100℃;